The Ei603TYCRF alarm is activated by heat from a fire, not smoke, which makes it ideal for kitchen installations where smoke detectors are prone to nuisance alarms.
The Ei603TYCRF has a 10 Year Lithium battery that is non replaceable.
The Ei603TYCRF is interconnected to other smoke / heat alarms in the dwelling or escape routes to ensure that all occupants are alerted to the danger.
Up to 12 battery powered smoke and heat alarms may be linked using hardwire or RF connectivity.
RadioLINK enabled smoke and/or heat alarms can be house coded as a system to prevent communication with other nearby RadioLINK systems.
Sensor |
Fast response thermistor (class A1) with threshold set to 58oC
|
Button Test: |
Pressing the test button tests the sensor, electronics and horn.
|
Battery Voltage: |
9V supplied by 10 Year Lithium Battery with 2,000mAh capacity.
|
Power-On Indicator: |
Red LED flashes through cover every 40 seconds
|
Alarm Indicator: |
Red LED flashes rapidly on the alarm sensing the fire and the sounder is activated. The sounders on all interconnected alarms are also activated.
|
Alarm: |
Piezoelectric-horn
|
Alarm Sound Output: |
85dB (A) (minimum) @ 3m
|
Normal Operating Temperature Range: | 0 to 40oC |
Humidity Range: |
15% to 95% Relative Humidity (non-condensing)
|
Hardwire Interconnect |
Interconnect up to12 alarms and remote control devices
|
RadioLINK Interconnect: |
Interconnect for up to12 battery powered RadioLINK alarms and remote control devices
|
Fixing: |
Screw fixings supplied
|
Dimensions: |
115mm (diameter) x 55mm (height)
|
Weight: | 200 grams |
Warranty: |
5 year (limited) warranty
|
Compliance: |
Kitemark to BS 5446-2:2003 , CE approved, Manufactured to ISO 9001:2000 quality standards.
|