fbpx

Quantec Controller (Model QT601-2)

QUANTEC CONTROLLER
(MODEL QT601-2)

The Quantec Controller supplies power to and controls a Quantec Addressable Call System. This monitors all network devices and manages the routing and distribution of all calls.

The Quantec Controller provides connections for network wiring, standby batteries, a laptop (for system programming), optional paging/DECT equipment, an optional printer or PC (to run Quantec’s QT707S Surveyor data management software). It can be semi-flush mounted using an QT385 bezel or fully-flushed using a BF359/3S stainless steel enclosure.

  • Supplies power to and controls a Quantec Addressable Call System.
  • Monitors all network devices and manages the routing and distribution of all calls.
  • Provides connections for network wiring, standby batteries, a laptop (for system programming),optional paging/DECT equipment, an optional printer or PC (to run Quantec’s QT707S Surveyor data management software).
  • Includes a library of 40 pre-set & 45 custom place names.
  • System setup requires a laptop PC running Quantec’s QT707 programming tools.
  • Can be semi-flush mounted using an QT385 bezel or fully-flushed using a BF359/3S stainless steel enclosure.
  • System wiring requires one or more QT603 network splitters.
  • Wiring should be made in a spine and limb arrangement using 1.5 to 2.5mm2 T&E (spines) and 4 to 8 core stranded security cable (limbs).
Mains supply 230V 50/60Hz.
Mains rated current
350mA maximum.
Internal power supply 27Vdc nominal.
Total output current limited to 3A @ 230Vac.
Quiescent current 100mA @ 24V
Max battery size and type
2 x 12V 7Ah VRLA connected in series.
Cabling
Spine & limb arrangement using QT603 network splitters. Spines wired in 1.5-2.5mm2 T&E; Limbs wired in 4 core stranded security cable (up to 6 limbs per QT603 splitter). Refer to main instructions for more details.
Open collector outputs
OP1 (active on standard call); OP2 (active on help req. call); OP3 (active on emergency call); OP4 (active on attack call). OP5 (failsafe fault output). Voltfree single pole c/o. Max. switch current 25mA; Max. switch voltage 30Vdc.
Other outputs
24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA.
    QUICK CONTACT

    Feel free to ask any questions over the phone, or get in touch via our contact form below. Your message will be dispatched directly to our staff who will answer as soon as they can.

    1 Step 1
    keyboard_arrow_leftPrevious
    Nextkeyboard_arrow_right